Product Details:
Payment & Shipping Terms:
|
Ranging Method: | 1ToF | Range Resolution: | ≤0.1m |
---|---|---|---|
Repeated Measurement Accuracy: | ±0.2m | Wavelength: | 905nm |
Laser Safety Level: | Class 1 | Range Of Working Temperature: | -40℃~+60℃ |
Survival Temperature Range: | -45℃~+65℃ | Working Humidity Range: | 0%~100% RH |
Enclosure Rating: | IP65 (or According To Specific Needs) | Working Acceleration Range: | -0.5g ~ 0.5g |
Luminous Flux 1: | 0° | Luminous Flux 2: | 2.05°±0.2° |
Luminous Flux 3: | 4.09°±0.2° | Real-time Data Products: | Device ID, Directly Measure Distance, Return Light Intensity, Data Valid Flag, System Status |
Fieldbus: | Profibus DP / Modbus RTU / CANopen Three Fieldbus Protocols, And RS485 Communication Can Be Customized | Operating Power Consumption: | Within 60W |
Supply Voltage And Maximum Current: | DC 24V, 3A | Size: | 200×200×250mm |
Highlight: | 60W Wind Measurement Lidar,Wind Measurement Lidar OEM,Wind Lidar Luminous flux 3 4.09 |
Wind Lidar Luminous flux 3 4.09°±0.2°
1,Product introduction
MolasCL can be installed in the front of the nacelle, by opening the nacelle, aligning the radar window with the opening, and detecting the fan blades downward. The opening is rectangular, the size is 140mm (parallel to the main axis) × 120mm. After completing the opening, after the calibration process, the radar is fixed on the nacelle shell by gluing.
2,Technical Data Sheet
Ranging index | |
Ranging method | 1ToF |
Detection distance | 200m@90% reflectivity/ 140m@10% reflectivity |
Range resolution | ≤0.1m |
Measurement accuracy | ±0.2m |
Repeated measurement accuracy | ±0.2m |
Resistance to ambient light | 100Klux |
Optical index | |
Wavelength | 905nm |
Repeat frequency | 20KHz per channel |
Laser safety level | Class 1 |
Environmental adaptability | |
Range of working temperature | -40℃~+60℃ |
Survival temperature range | -45℃~+65℃ |
Working humidity range | 0%~100% RH |
Enclosure rating | IP65 (or according to specific needs) |
Working acceleration range | -0.5g ~ 0.5g |
Beam pointing | |
Luminous flux 1 | 0° |
Luminous flux 2 | 2.05°±0.2° |
Luminous flux 3 | 4.09°±0.2° |
Output measurement results | |
Real-time data products |
Device ID, directly measure distance, return light intensity, Data valid flag, system status |
Fieldbus | Profibus DP / Modbus RTU / CANopen Three fieldbus protocols, and RS485 communication can be customized |
Qther | |
Operating power consumption | Within 60W |
Supply voltage and maximum current | DC 24V, 3A |
Size | 200×200×250mm |
Contact Person: ivyyao
Tel: +86 13072523225
Fax: 86-025-86800073