Product Details:
Payment & Shipping Terms:
|
Ranging Method: | 1ToF | Detection Distance: | 200m@90% Reflectivity/ 140m@10% Reflectivity |
---|---|---|---|
Range Resolution: | ≤0.1m | Measurement Accuracy: | ±0.2m |
Repeated Measurement Accuracy: | ±0.2m | Resistance To Ambient Light: | 100Klux |
Wavelength: | 905nm | Repeat Frequency: | 20KHz Per Channel |
Laser Safety Level: | Class 1 | Range Of Working Temperature: | -40℃~+60℃ |
Survival Temperature Range: | -45℃~+65℃ | Working Humidity Range: | 0%~100% RH |
Enclosure Rating: | IP65 (or According To Specific Needs) | Luminous Flux 3: | 4.09°±0.2° |
Real-time Data Products: | Device ID, Directly Measure Distance, Return Light Intensity, Data Valid Flag, System Status | Fieldbus: | Profibus DP / Modbus RTU / CANopen Three Fieldbus Protocols, And RS485 Communication Can Be Customized |
Operating Power Consumption: | Within 60W | Supply Voltage And Maximum Current: | DC 24V, 3A |
Size: | 200×200×250mm | ||
High Light: | ODM Wind Measurement Lidar,OEM Wind Measurement Lidar,wind speed lidar 60C Work Temp |
Wind Lidar Range of working temperature -40℃~+60℃
1,Product introduction
MolasCL laser clearance monitoring radar is a kind of lidar that monitors the blade tip clearance distance in real time. When the monitored blade clearance value is close to the specified minimum clearance value, the main control of the fan unit can immediately take protective measures, such as deceleration, propeller retraction, etc.
2,Technical Data Sheet
Ranging index | |
Ranging method | 1ToF |
Detection distance | 200m@90% reflectivity/ 140m@10% reflectivity |
Range resolution | ≤0.1m |
Measurement accuracy | ±0.2m |
Repeated measurement accuracy | ±0.2m |
Resistance to ambient light | 100Klux |
Optical index | |
Wavelength | 905nm |
Repeat frequency | 20KHz per channel |
Laser safety level | Class 1 |
Environmental adaptability | |
Range of working temperature | -40℃~+60℃ |
Survival temperature range | -45℃~+65℃ |
Working humidity range | 0%~100% RH |
Enclosure rating | IP65 (or according to specific needs) |
Working acceleration range | -0.5g ~ 0.5g |
Beam pointing | |
Luminous flux 1 | 0° |
Luminous flux 2 | 2.05°±0.2° |
Luminous flux 3 | 4.09°±0.2° |
Output measurement results | |
Real-time data products |
Device ID, directly measure distance, return light intensity, Data valid flag, system status |
Fieldbus | Profibus DP / Modbus RTU / CANopen Three fieldbus protocols, and RS485 communication can be customized |
Qther | |
Operating power consumption | Within 60W |
Supply voltage and maximum current | DC 24V, 3A |
Size | 200×200×250mm |
Contact Person: ivyyao
Tel: +86 13072523225
Fax: 86-025-86800073