Product Details:
Payment & Shipping Terms:
|
Ranging Method: | 1ToF | Detection Distance: | 200m@90% Reflectivity/ 140m@10% Reflectivity |
---|---|---|---|
Range Resolution: | ≤0.1m | Measurement Accuracy: | ±0.2m |
Repeated Measurement Accuracy: | ±0.2m | Resistance To Ambient Light: | 100Klux |
Wavelength: | 905nm | Repeat Frequency: | 20KHz Per Channel |
Laser Safety Level: | Class 1 | Range Of Working Temperature: | -40℃~+60℃ |
Working Acceleration Range: | -0.5g ~ 0.5g | Luminous Flux 1: | 0° |
Luminous Flux 2: | 2.05°±0.2° | Luminous Flux 3: | 4.09°±0.2° |
Real-time Data Products: | Device ID, Directly Measure Distance, Return Light Intensity, Data Valid Flag, System Status | Fieldbus: | Profibus DP / Modbus RTU / CANopen Three Fieldbus Protocols, And RS485 Communication Can Be Customized |
Operating Power Consumption: | Within 60W | Supply Voltage And Maximum Current: | DC 24V, 3A |
Size: | 200×200×250mm | ||
High Light: | Molas CL Lidar Wind Measurement Devices,Lidar Wind Measurement Devices -45C,60W wind detection lidar |
Wind Lidar Survival temperature range -45℃~+65℃ Molas CL
1,Product introduction
The application of headroom radar on existing units can prevent tower sweeping, lift the power limit of dangerous units and increase power generation. The application of headroom radar on future units can reduce blade costs and reduce unit design pressure.
2,Technical Data Sheet
Ranging index | |
Ranging method | 1ToF |
Detection distance | 200m@90% reflectivity/ 140m@10% reflectivity |
Range resolution | ≤0.1m |
Measurement accuracy | ±0.2m |
Repeated measurement accuracy | ±0.2m |
Resistance to ambient light | 100Klux |
Optical index | |
Wavelength | 905nm |
Repeat frequency | 20KHz per channel |
Laser safety level | Class 1 |
Environmental adaptability | |
Range of working temperature | -40℃~+60℃ |
Survival temperature range | -45℃~+65℃ |
Working humidity range | 0%~100% RH |
Enclosure rating | IP65 (or according to specific needs) |
Working acceleration range | -0.5g ~ 0.5g |
Beam pointing | |
Luminous flux 1 | 0° |
Luminous flux 2 | 2.05°±0.2° |
Luminous flux 3 | 4.09°±0.2° |
Output measurement results | |
Real-time data products |
Device ID, directly measure distance, return light intensity, Data valid flag, system status |
Fieldbus | Profibus DP / Modbus RTU / CANopen Three fieldbus protocols, and RS485 communication can be customized |
Qther | |
Operating power consumption | Within 60W |
Supply voltage and maximum current | DC 24V, 3A |
Size | 200×200×250mm |
Contact Person: ivyyao
Tel: +86 13072523225
Fax: 86-025-86800073